| Tên cảm biến | Đặc tính kỹ thuật | Sử dụng thay thế cho | |
| Hãng sản xuất | Model/Part | ||
Max-1![]() |
- Output17.0 ± 3.0 mV - Response Time≤ 13 seconds - Linearity< 3.0% of full scale - Tải Thông số kỹ thuật |
Analytical Industries | PSR-11-915 |
| Datascope | Multinex Analyzer | ||
| GE (Datex-Ohmeda) | 0237-2034-700 Excel | ||
| GE (Ohmeda) | 5120, 5100, 5250 RGM, 4700 Oxicap, 7800, 5125, 5150, Handheld Monitor, 0237-2034-700, Excel Modulus | ||
| HP | 15201A | ||
| Mercury Medical | 10-103-07 | ||
| Pacifitech | PT-10 | ||
| Teledyne | R15 #C-41131 | ||
| Teleflex | 5556 | ||
| VTI | 100352, 101272, 100352 | ||
Max-2![]() |
Output12.2 to 18.1 mV Response Time≤ 15 seconds Linearity± 1.0% of full scale Tải Thông số kỹ thuật |
Analytical Industries | PSR-11-915-1 |
| Drager | 6803290, 6850645, Narkomed, Fabius GS, Tiro | ||
| Hewlett Packard | Magnitude,Invivo,15201A | ||
| Mercury Medical | 10-103-12 | ||
| Pacifitech | PT-24 | ||
| Teledyne | R31 | ||
| VTI | 101372, 101372 | ||
Max-7![]() |
Output8.0 to 12.0 mV Response Time≤ 12 seconds Linearity± 2.0% of full scale Tải Thông số kỹ thuật |
Precision Medical | 505327 |
| Teledyne | R17MED #C-43690, AX/MX300 Series, R17MED #C-43690 | ||
Max-7L![]() |
Output8.0 to 12.0 mV Response Time≤ 12 seconds Linearity± 2.0% of full scale Tải Thông số kỹ thuật |
||
Max-8![]() |
Output12.2 to 18.1 mV Response Time≤ 15 seconds Linearity± 1.0% of full scale Tải Thông số kỹ thuật |
Analytical Industries | PSR-11-915-3 |
| GE (Datex-Ohmeda) | 0237-2034-700 Excel Modulus, 5250 RGM, 5150 Handheld Monitor | ||
| GE (Ohmeda) | 5120, 5100, 5250 RGM, 5250 (ext. only), 5125, 5150, 0237-2034-700, Excel Modulus | ||
| Mercury Medical | 10-103-13 | ||
| Teledyne | R32MED #B-73463 | ||
| VTI | 101272 | ||
Max-9![]() |
Output26.4 to 44.0 mV Response Time≤ 11 seconds Linearity± 2.0% of full scale Tải Thông số kỹ thuật |
Analytical Industries |
PSR-11-55 |
| HillRom | 6736140 | ||
| Mercury Medical | 10-103-03 | ||
| Pacifitech | PT-05 | ||
| Teledyne | R13 #B-39636 | ||
| Teleflex (Hudson) | 5500, V-05, 5590, 5577, 5584, 5595, 6477 | ||
Max-10![]() |
Output8.0 to 13.5 mV Response Time0 to 90% in 15 seconds Linearity± 2% of full scale |
Analytical Industries | PSR-11-915-4 |
| EnviteC | OOM-110 | ||
| City Technology | MOX-7 | ||
| GE (Ohmeda) | 6050-0004-110, Modulus SE, 7900 Series, Aisys, Aestiva Series, SmartVent S-5, Aespire, Avance | ||
| International Technologies | M-10 | ||
| Mercury Medical | 10-103-10 | ||
| Pacifitech | PT-20A | ||
| Teledyne | R30MED #B-72939 | ||
Max-11![]() |
Output17.0 ± 3.0 mV Response Time≤ 13 seconds Linearity |
Analytical Industries | MOX-16 |
| Drager | 6803290, 6850645, Narkomed, Fabius GS, Evita Family, Babylog, Cato, Fabius Series | ||
| EnviteC | OOM-201 | ||
| HillRom | PSR-11-915-2 | ||
| International Technologies | M-02 | ||
| Invivo | Magnitude | ||
| Mercury Medical | 10-103-07 | ||
| Pacifitech | PT-14A | ||
| Teledyne | R23 #C-61139 | ||
| Teleflex (Hudson) | 5557, V-14 | ||
| VTI | 101372, 100352, 101372, 100352 | ||
Max-11i![]() |
Output17.0 ± 3.0 mV Response Time≤ 12 seconds Linearity< 3.0% of full scale |
Drager | Incubators, 18000 High Temp App |
Max-12![]() |
Output14.5 ± 1.5 mV Response Time≤ 13 seconds Linearity< 2% relative |
Analytical Industries | PSR-11-917-M |
| City Technology | MOX-9 | ||
| Datascope | 0600-00-0002 (MAX-12f) | ||
| EnviteC | OOM-202 | ||
| Hamilton | 396008, 396009, Galileo, Raphael, Arabella, Aladdin, 51254, G5, Arabella | ||
| IMT | PF300 | ||
| International Technologies | M-04 | ||
| MSA | 472062, 470644 | ||
| Mercury Medical | 10-103-06 | ||
| Pacifitech | PT-12A | ||
| Sensidyne | Acutonic Hi Freqency Jet Ventilator, 00M102 | ||
| Siemens | 9004979-E347E | ||
| Spacelabs | 90513, Capnograph | ||
| Taema | YR049700, Cesar-2, Horus- | ||
| Teledyne | R24MED #B-62321 | ||
| Teleflex (Hudson) | 5556, V-12 | ||
| VTI | 103100 | ||
Max-12a![]() |
Output17.0 ± 14.0 mV Response Time≤ 12 seconds Linearity± 3.0% of full scale |
HillRom | Isolette Incubator |
| Philips (Respironics) | NeoPAP | ||
Max-12c![]() |
Output8.0 to 13.0 mV Response Time≤ 6 seconds Linearity≤ 3% |
Viasys | Avea Ventilator, Infant SiPaP |
Max-13![]() |
Output9.0 to 17.0 mV Response Time≤ 13 seconds Linearity< 3% error |
Analytical Industries [PSR-11-917-J] City Technology [MOX-2] Covidien [4-020933-00, 7820 Monitor, 7200 Vent] Datascope [Anestar S] EnviteC [OOM-102-1] HillRom [6735142] Invivo [9445 Sensor] MSA [406931, MiniOX 3000, MiniOX II, MiniOX III] Mercury Medical [10-103-05] Pacifitech [PT-11A] Philips (Respironics) [Criterion Vent, Espirit Vent Lifecare (#PLV-102), 37-079 Sensor] Precision Medical [PM5900, 504877] Teledyne [R17MED #C-43690, R17MED #C-43690] Teleflex (Hudson) [5567, V-11] VTI [100580] Viasys [66030 Sensor, 6400 Vent, 8400 Vent, VIP Vent] |
|
Max-13c![]() |
Output13.0 to 17.0 mV Response Time≤ 13 seconds Linearity< 3% error |
BioMed Devices [4433] | |
Max-13-250![]() |
Output12.0 to 17.0 mV Response Time≤ 15 seconds Linearity± 1.0% of full scale |
Analytical Industries [PSR-11-917-J] Covidien [4-020933-00, 7820 Monitor, 7200 Vent] Datascope [Anestar S] HillRom [6735142] Invivo [9445 Sensor] MSA [406931, MiniOX 3000, MiniOX II, MiniOX III] Mercury Medical [10-103-05] Pacifitech [PT-11A] Philips (Respironics) [Criterion Vent, Espirit Vent Lifecare (#PLV-102), 37-079 Sensor] Teledyne [R17 #C-43690] Teleflex (Hudson) [5567] VTI [100580] Viasys [66030 Sensor, 6400 Vent, 8400 Vent, VIP Vent] |
|
Max-14![]() |
Output9.0 to 13.0 mV Response Time≤ 13 seconds Linearity< 3% error |
Devilbiss [02ANA-101 Sensor] MSA [806572, MiniOX 1A] Mercury Medical [10-103-13] Pacifitech [PT-26] |
|
Max-16![]() |
Output8.5 to 15.0 mV Response Time≤ 30 seconds Linearity± 1% full scale error maximum |
Covidien [4-072214-00, 840, 740, 760, PB2000 Tester] | |
Max-17![]() |
Output7.5 to 12.5 mV Response Time≤ 8 seconds Linearity< 3.0% of full scale |
Analytical Industries [PSR-11-77] City Technology [MOX-4] EnviteC [OOM-105] International Technologies [M-07] Mercury Medical [10-103-02] Pacifitech [PT-03] Penlon [MTS] Teledyne [T-7] Teleflex (Hudson) [5558, V-0 |
|
Max-19![]() |
Output20 ± 4 mV Response Time≤ 13 seconds Linearity< 3% |
Analytical Industries [PSR-11-33-1] Hamilton [HM-01, Veolar, Amadeus, Arabella] Mercury Medical [10-103-00] Pacifitech [PT-01] Teledyne [T1 #A-37016] Teleflex (Hudson) [5565, 5568, C1, C-01] |
|
Max-18![]() |
Output20 ± 4 mV Response Time≤ 13 seconds Linearity< 3% |
Analytical Industries [PSR-11-33-1] Mercury Medical [10-103-01] Pacifitech [PT-02] Teledyne [C1R #B-39022] Teleflex (Hudson) [5569, V-02, 5525, 5528, 5529, 5550, 5552] |
|